ennoLogic Volt mA Thermocouple Loop Process Calibrator eC370T - 0-20V and 4-20mA Simulator – Portable Millivolt mA and Temperature Signal Generator and Meter for Transmitters Current Loops PLC

  • VERSATILE AND ACCURATE VOLT MA THERMOCOUPLE CALIBRATOR: Signal generator, simulator and volt / mA meter for calibrating, testing and repairing milliamp loops, thermocouples, PLC, temperature control and HVAC systems. Easily generate precise test signals for current and voltage devices (mA, mV, V, Celsius and Fahrenheit ranges)..
  • NUMERIC KEYPAD for ease and flexibility in setting output signals configuring options. HOTKEY programming for each numeric key (long-press immediately outputs user-configured voltage, current or temperature signal). RAMP AND LADDER OUTPUT FUNCTIONS can be custom configured. BUILT-IN 24V LOOP SUPPLY lets you power and read a device or transmitter without needing another multimeter. This greatly simplifies testing 2-wire current loops..
  • MEASURE VOLTAGE OUTPUT SIGNALS from process devices and sensors with two input ranges of 0-100mV (0.01mV resolution, 0.06% accuracy) and 0-20V (1mV resolution, 0.08% accuracy). MEASURE CURRENT TRANSMITTERS within a range of 0 to 24mA with 0.001mA resolution and 0.08% accuracy. MEASURE THERMOCOUPLE TEMPERATURES within a range of -250°C to +1800°C and resolution of ±0.7°C to ±2°C (range and resolution depends on thermocouple type, supported are type K, J, E, T, N, S, R, and B.).
Check Stock

K-Type Scientific Digital Thermometer DM6801 with high Temperature thermocouple PK-1000

  • Digital k-type thermometer with one input and extra thermocouple PK-1000.
  • Temperature Range: -58.0 to 1999.0 °F (-50.0 to 1300.0 °C).
  • Resolution: 0.1°F or °C or K Accuracy: 2.2° or 0.75% Data Hold.
  • Comes with k-type thermocouple wire probe that measures up to 1832 degree fahrenheit (1000 degree Celsius).
  • Battery: 9V (included!) Dimensions: 6" x 3" x 1.5" (149 x 71 x 41 mm) Weight: 7 oz (200 g).
Check Stock

Amprobe TMD-50 Thermocouple Thermometer K-type

  • Portable, dual-input thermometer for reading temperatures from two sources simultaneously, and is used in quality control and HVAC, electrical, industrial, and automotive maintenance.
  • Dual-scale temperature readings range from -328 to 2,498 degrees F (-200 to 1,370 degrees C).
  • Dual-input thermocouples for superheat and subcool applications, and cut-out and cut-in temperature measurements, and offset mode compensates for thermocouple error.
  • Backlit LCD screen with a data hold feature to save temperature readings for later viewing, maximum and minimum temperature with elapsed time, average and relative temperature calculations, and low battery indicator.
Check Stock

GMAX-GF is Camera GPS BDS Receiver & Bluetooth Shutter Release for Nikon Df D750 D610 D600 D7500 D7200 D7100 D7000 D5600 D5500 D5300/5200/5100/5000 D3400 D3300/3200/3100 1900mAh Li-ion

  • Embeds location, time, shooting direction into every video or image EXIF for Nikon Df, D750, D610, D600, D7500, D7200, D7100, D7000, D5600, D5500,....
  • Dual-positioning systems: GPS and BeiDou (BDS) provide 20% more location accuracy than GPS alone, faster signal acquisition.
  • Can act as a stand-alone "Trace Logger" while sailing, hiking, flying, skiing, traveling, etc. 4GB Course Logger plus altitude & speed data, runs....
  • Measures Barometric or GPS/BDS altitude, user can choose their preferred altitude data base on actual environment.
  • Bluetooth technology enables the iPhone itself used as a remote triggering device for the user's DSLR camera. 2 years Mfg. Warranty!.
Check Stock

Elitech RC-5 USB Temperature Data logger Recorder 32000 Points High Accuracy

  • Multi-use temperature data logger,high accuracy sensor,up to 32,000 recording points.
  • Built-in USB connector, no cable required to download and manage data.
  • Up to 6 months battery life, replaceable battery, low power consumption.
  • 【Please email/message us for the calibration certificate.】Powerful LCD Indication, more intuition display on key information. 24/7 US Technician Support via Email and Phone..
Check Stock

Fluke 568 Dual Infrared Thermometer, -40 to +1472 Degree F Range, Contact/Non Contact

  • Dual infrared and thermocouple thermometer for noncontact or contact temperature measurement in electrical maintenance and monitoring industrial and manufacturing processes.
  • Measures temperature with the infrared sensor from -40 to +800 degrees C (-40 to +1472 degrees F) with an accuracy of + or - 1 degree C (+ or - 2 degrees F).
  • Measures temperature with the included Type K bead thermocouple from -40 to +260 degrees C (-40 to +500 degrees F).
  • 50:1 infrared distance-to-spot ratio with laser sighting for pinpointing the measurement area.
  • Stores up to 99 points of data for analysis and monitoring on a computer.
Check Stock

Elitech RC-5 USB Temperature Data Logger Recorder 32000 Points High Accuracy (10 Pack)

  • Multi-use temperature data logger, 32,000 recording points, with wide measuring range -30℃~70℃ / -22℉~158℉. Up to 6 months battery life, replaceable battery, low power consumption..
  • Built-in USB connector, no cable or reader required to download data or generate PDF report..
  • Powerful LCD indication, easy to view temperature data, logged points, alarm status, and more key information, etc. Fahrenheit/Celsius switchable through free software..
  • IP65 protection grade and temperature alarms, suitable to use on dry ice and vaccine storage, transportation and etc..
  • PLEASE EMAIL/MESSAGE US FOR THE CALIBRATION CERTIFICATE. 24/7 US Technician Support via Email and Phone..
Check Stock

Digital Vibrometer,GM63B Vibration Meter Speed Acceleration Displacement Measurement Split Type Handheld Portable Vibration Measurer

  • Digital Vibration Meter:Using piezoelectric ceramic acceleration sensor, vibration collection is more accurate..
  • High Accuracy Vibrometer:Accurate value, three and a half digits display, can display the value more realistically..
  • Pocket Vibrometer:Portable design, handheld body, more convenient to use, can be used in various situations..
  • Mechanical Vibration Meters:Support temperature conversion and environment display, able to display modes according to different environments..
  • Industrial Data Logger:LCD screen display, data is clearly visible, it is more convenient to analyze and measure data..
Check Stock

FLUKE FLUKE-62 MAX+ INFRARED THERMOMETER, -30C to +650C / -22F to +1202F

  • Dual infrared and thermocouple thermometer for noncontact or contact temperature measurement in electrical maintenance and monitoring industrial and manufacturing processes.
  • Measures temperature with the infrared sensor from -40 to +800 degrees C (-40 to +1472 degrees F) with an accuracy of + or - 1 degree C (+ or - 2 degrees F).
  • Measures temperature with the included Type K bead thermocouple from -40 to +260 degrees C (-40 to +500 degrees F).
  • 50:1 infrared distance-to-spot ratio with laser sighting for pinpointing the measurement area.
  • Stores up to 99 points of data for analysis and monitoring on a computer.
Check Stock