Reviews Arc Fault Breaker
Square D by Schneider Electric HOM2040M100PRB Homeline 100 Amp 20-Space 40-Circuit Outdoor Main Breaker Load Center (Plug-on Neutral Ready),
- Homeline, 100A Main Breaker Installed Load Center.
- Combination Cover For Flush Or Surface Mount.
- Includes a fully distributed neutral bar, allowing for the installation of Homeline Plug-on Neutral combination arc fault breakers on any space.
- Each pole space accepts full-size, tandem or quad breakers.
- Ground and neutral bars accept up to (3) #10-14 equipment grounds.
- Accommodates plug-on secondary surge arrestor (sold separately).
Check StockSurface Mount Circuit Breaker, Auto Reset, 3/8\ Stud, 300A
- Meet S.A.E. J1625, J1171, UL1500 (Ignition Protected),"Trip Free" design cannot be held "ON" during fault current condition.
- 300A DC Surface Mount circuit breaker combines switching and circuit protection into a single device,Terminal Size: 5/16"-18.
- Housing is thermalplastic UL rated 94V0, "Trip Free" design cannot be held "ON" during fault current condition.
- Max voltage: 48V DC, Interrupt capacity: 5000A @12V, 3000A @ 24V, 1500A @ 42V.
- Manual Reset Circuit Breaker,can also be used as an on/off button switch for the battery Boat Marine RV Yacht Battery Trailer Bus Truck Solar.
Check StockQ2125 125-Amp Double Pole Type QP Circuit Breaker
- This 30-20 amp double breaker is a twin single-pole tandem type breaker that works with 120 volts and has a 10,000 AIC interrupting rating..
- With ground fault equipment protection, this breaker is suitable for use in Siemens panels that allow CTL type breakers..
- This RV circuit breaker accepts #14-6 AWG or #14-6 Al wire and is thermal-magnetic. HACR SWD rated and UL listed, this circuit breaker is a standard trip interruption type..
Check StockBussmann CB285-80 Surface-Mount Circuit Breakers, 80 Amps (1 per pack)
- Meet S.A.E. J1625, J1171, UL1500 (Ignition Protected),"Trip Free" design cannot be held "ON" during fault current condition.
- 50A DC Surface Mount circuit breaker combines switching and circuit protection into a single device,Terminal Size: 5/16"-18.
- Housing is thermalplastic UL rated 94V0, "Trip Free" design cannot be held "ON" during fault current condition.
- Max voltage: 48V DC, Interrupt capacity: 5000A @12V, 3000A @ 24V, 1500A @ 42V.
- Manual Reset Circuit Breaker,can also be used as an on/off button switch for the battery Boat Marine RV Yacht Battery Trailer Bus Truck Solar.
Check StockExtech - 1218G94EA - CB10 Circuit Breaker Finder Locates fuses/breakers Tests receptacles and GFCI circuits
- Quickly locate 110V to 125VAC Circuit Breakers and Fuses.
- Variable Sensitivity adjustment to pinpoint correct circuit breaker.
- Bright Red and Green LEDs indicates if receptacle is correctly wired or six fault conditions.
- Simply plug the GFCI Transmitter into an outlet and trace for the correct breaker at the electrical box.
- Audible and visual circuit breaker indication.
Check StockKlein Tools RT310 Outlet Tester, AFCI and GFCI Receptacle Tester for North American AC Electrical Outlets
- GFCI Tester detects the most common wiring faults in standard, AFCI, and GFCI electrical outlets.
- Test AFCI devices by simulating arc fault conditions.
- Test GFCI devices by simulating ground fault conditions.
- Capable of detecting a dual-open wiring fault with simultaneous open neutral and open ground wires (patent pending technology).
- Tester delivers clear visual indication of the wiring condition at the electrical outlet.
Check StockPlasma Cutter, HeroCut 45i, 110 Voltage IGBT Inverter Air Plasma Cutter 6mm Clean Cut, 10mm Severance Cut In 70PSI (CUT45i 110v)40A or 63A Power Breaker is suggested
- Plasma Cutter Input Voltage 110V, 60Amps Power breaker is suggested. 40Amps cutting current,High frequency arc starting, Quality cutting thickness 6mm, Severance cutting thickness [email protected] 40Amps.
- Very compact design, Adopt Latest IGBT inverter technology, Easy cut stainless steel, Alloy Steel, Mild Steel, Thin Copper, Aluminum, It is High Frequency Arc Starting. 1 year warranty for machine..
- Input voltage is 110V 50/60Hz, 60Amps Power breaker is suggested. Machine maybe explode if plug it to 220V, Make sure you fix machine to correct voltage, Better use 60Amps power breaker for this machine..
- 40Amps output, Duty cycle 60% in 40Amps, 100% in 35Amps, Air pressure range from 40-70PSI, Maybe the cutting arc not stable if the air less or over the range..
- We supply high quality machine, very lightweight but powerful, Very easy to carry, Machine come with quality accessories and torch parts, Easy cut stainless steel, Alloy Steel, Mild Steel, Thin Copper, Aluminum. ( search torch consumables at amazon ASIN: B08BCLNL5B ).
Check StockSquare D - QO120GFICP QO Qwik-Gard 20 Amp Single-Pole GFCI Circuit Breaker
- 20 Amp Circuit Breaker And Ground Fault Circuit Interrupter All In One.
- Red Visi-Trip Feature Shows Which Breaker Has Been Tripped.
- Use To Provide Protection On All Outdoor, Bath And Kitchen Circuits.
- Use In All Square D QO Load Centers 100A Or Higher And In Some Smaller QO Load Centers.
Check StockGE THQL1115DF Single-Pole Dual Function Plug-in Afci/Gfci Circuit Breaker, 120 Vac, 15 Amp, 10 Kaic
- GE's Dual Function Circuit Interrupter (DFCI) provides ground fault and arc fault circuit protection in one unit.
Check Stock